APPLICATION FIELD:

Electric vehicle transmission powertrain testing

Fuel cell stack testing

High voltage UPS testing

Discharge testing of power batteries and lead-acid batteries

High power energy storage inverter testing

FEATURES:

➊ Single machine rated power 40-500kW Output voltage range 400-2000V, output current range 200-2000A

➋ Automatic phase sequence recognition, adaptive power grid

➌ The load mode has CC, CV, CR, and CP modes

➍ Dual directional flow of energy, 100% energy feedback

➎ Power factor ≥ 0.99, total current waveform distortion rate ≤ 3%

➏ The ten inch LCD screen provides a more intuitive human-machine interaction interface and display operation

SOFTWARE WAVEFORM INTERFACE

Product Mode

Specification Category / ParameterVEADL-40-400VEADL-80-400VEADL-100-400VEADL-100-1000VEADL-100-1200> VEADL-200-800> VEADL-200-1200VEADL-250-800VEADL-250-1200VEADL-300-800VEADL-300-1200
DC (Input Characteristics)Voltage Range20-800V20-800V20-800V20-800V20-800V20-800V20-800V20-800V20-800V20-800V20-800V
Current Range-400-400A-400-400A-400-400A-1000-1000A-1200-1200A-800-800A-1200-1200A-800-800A-1200-1200A-800-800A-1200-1200A
Output Voltage Accuracy≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS
Source Effect≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS
Load Effect≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS≤0.05%FS
Voltage Ripple (rms)≤0.2%FS≤0.2%FS≤0.2%FS≤0.2%FS≤0.2%FS≤0.2%FS≤0.2%FS≤0.2%FS≤0.2%FS≤0.2%FS≤0.2%FS
Response Time (10%-90%)≤3-5ms≤3-5ms≤3-5ms≤3-5ms≤3-5ms≤3-5ms≤3-5ms≤3-5ms≤3-5ms≤3-5ms≤3-5ms
Positive/Negative Switching Time (-90%-90%)≤7-10ms≤7-10ms≤7-10ms≤7-10ms≤7-10ms≤7-10ms≤7-10ms≤7-10ms≤7-10ms≤7-10ms≤7-10ms
Overload Time (Customizable)60s60s60s60s60s60s60s60s60s60s60s
Current Setting Resolution0.1A0.1A0.1A0.1A0.1A0.1A0.1A0.1A0.1A0.1A0.1A
Voltage Setting Resolution0.1V0.1V0.1V0.1V0.1V0.1V0.1V0.1V0.1V0.1V0.1V
Power Setting Resolution0.1kW0.1kW0.1kW0.1kW0.1kW0.1kW0.1kW0.1kW0.1kW0.1kW0.1kW
AC (Output Characteristics)Input Wiring Mode3-Phase 3-Wire + Ground3-Phase 3-Wire + Ground3-Phase 3-Wire + Ground3-Phase 3-Wire + Ground3-Phase 3-Wire + Ground3-Phase 3-Wire + Ground3-Phase 3-Wire + Ground3-Phase 3-Wire + Ground3-Phase 3-Wire + Ground3-Phase 3-Wire + Ground3-Phase 3-Wire + Ground
Output Voltage380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%
Frequency50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%
Power Factor≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99
Total Current Harmonic Distortion≤3%≤3%≤3%≤3%≤3%≤3%≤3%≤3%≤3%≤3%≤3%
Feedback CharacteristicsAC Voltage380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%380Vac±10%
Frequency50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%50Hz±10%
Power Factor≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99
Total Current Harmonic Distortion≤3%≤3%≤3%≤3%≤3%≤3%≤3%≤3%≤3%≤3%≤3%
Feedback PowerFull Power FeedbackFull Power FeedbackFull Power FeedbackFull Power FeedbackFull Power FeedbackFull Power FeedbackFull Power FeedbackFull Power FeedbackFull Power FeedbackFull Power FeedbackFull Power Feedback
Communication InterfaceRS485 (Standard), CAN (Standard), LAN (Optional), GPIB (Optional)
Device FunctionElectronic Load Function
Safety CharacteristicsProtection ModeUnderfrequency, Overfrequency, AC Overvoltage, AC Overcurrent, AC Undervoltage, Phase Loss, Leakage Current Protection; Over Temperature Protection, Overvoltage Protection, Overcurrent Protection, Overload Protection, Short Circuit Protection
Withstand Voltage and Insulation ResistanceWithstand Voltage: 1800VAC 60S, Leakage Current < 10mA; 1000VDC 60S, Resistance ≥10MΩ; 2000VDC 60S, No Arc, No Breakdown
Noise (1m from Cabinet)≤75dB
Protection GradeIP21
Cooling MethodForced Air Cooling (Controllable)
Working EnvironmentTemperature-10℃-45℃
Humidity10-90% (Non-Condensing)
Altitude2000m
VEADL-800V
VEADL-800V
VEADL-800V
VEADL-800V
VEADL-800V
VEADL-800V
VEADL-800V
VEADL-800V
VEADL-800V
VEADL-800V
+
  • VEADL-800V
  • VEADL-800V
  • VEADL-800V
  • VEADL-800V
  • VEADL-800V
  • VEADL-800V
  • VEADL-800V
  • VEADL-800V
  • VEADL-800V
  • VEADL-800V

VEADL-800V

The VEADL series is a high-power feedback electronic load that can convert absorbed DC energy into AC energy through power electronic conversion and feed it back to the grid to save energy. It has the characteristics of high precision and high dynamic response.

Contact

szwrddq@163.com

400-111-0655

Category:

Electronic Load