APPLICATION FIELD:

Performance testing of small capacity battery charging and discharging

inverter test

Semiconductor IC Device Testing

Power module testing

Automotive Electronics

FEATURES:

➊ High-power-density source-load integrated design, 1U Mini size

➋ Single-unit rated power 400W/800W, output voltage range 60-600V,Output current range 3-30A

➌ CC/CV loop priority selection, photovoltaic simulation function, battery simulation function, battery testing function, CC/CV priority LIST function

➍ Voltage and current output slopes can be adjusted

➎ Adapt to different standard power grids 110V/60Hz or 220V/50Hz

➏ Equipped with DC pre charging function to prevent surge current caused by misoperation from damaging the power supply itself or the tested object

➐ Automatic voltage compensation and anti reverse protection

➑ Rich peripheral interfaces: standard RS232/CAN/LAN/USB/RS485

① Output endE ② Compensation interface ③USB

④ Communication interface (CAN/RS232/RS485/)

⑤ LAN ⑥ External temperature collection ⑦ Parallel interface

PRODUCT FEATURES:

Seamless switching of power/load

Unlike traditional power sources and loads, there may be brief jumps and discontinuities during the switching of positive and negative currents. VEM integrates bidirectional power supply and feedback load functions, enabling high-speed conversion between source and load current modes, enabling seamless and fast switching between output and absorption currents, effectively avoiding voltage or current overshoot. It is widely used for testing energy storage devices such as batteries, battery packaging, and battery protection boards.

Battery simulation function

The VEM series can simulate up to 99 battery series and parallel connections. Users can quickly define the battery model by setting the voltage, capacity, resistance, and SOC of the battery through the front panel of the power supply.

Battery testing function

The VEM series has battery charging function and can perform charging tests on the battery. Users can set four test shutdown conditions for the battery through the panel: shutdown voltage, shutdown current, shutdown capacity, and charging time. When any one of the four conditions is met, the test will be automatically interrupted. During the testing process, the voltage, charging time, and charged capacity of the battery can be observed.

Product Model:

Specification CategoryVEM04-6030VEM08-6030VEM04-15012VEM08-15012
Rated Value (0~50℃)Output Voltage0-60V0-60V0-150V0-150V
Output Current-30A-30A-30A-30A-12A-12A-12A-12A
Output Power-400W-400W-800W-800W-400W-400W-800W-800W
Minimum Operating Voltage6V at -30A6V at -30A15V at -12A15V at -12A
Constant Current ModeAdjustment Range-30A-30A-30A-30A-12A-12A-12A-12A
Setting Resolution10mA10mA1mA1mA
Accuracy<0.1%FS<0.1%FS<0.1%FS<0.1%FS
Constant Voltage ModeAdjustment Range0-60V0-60V0-150V0-150V
Setting Resolution1mV1mV10mV10mV
Accuracy<0.1%FS<0.1%FS<0.1%FS<0.1%FS
Programmable Internal ResistanceAdjustment Range0-1000mΩ0-1000mΩ0-1000mΩ0-1000mΩ
Setting Resolution0.1mΩ0.1mΩ0.1mΩ0.1mΩ
Accuracy2%+6max2%+6max2%+6max2%+6max
Constant Power ModeAdjustment Range-400W-400W-800W-800W-400W-400W-800W-800W
Setting Resolution0.1W0.1W0.1W0.1W
Accuracy<1.0%FS<1.0%FS<1.0%FS<1.0%FS
Constant Resistance ModeAdjustment Range0.6-1000Ω0.6-1000Ω1.5-1000Ω1.5-1000Ω
Resolution0.1Ω0.1Ω0.1Ω0.1Ω
AccuracyPin: Vreal×Ireal×0.1%/Rset +Irmax×0.2% Pmax: Vreal×Irmax×0.1%/Rset +Irmax×0.2%
Current Readback ValueMeasuring Range-30A-30A-30A-30A-12A-12A-12A-12A
Resolution1mA1mA1mA1mA
Accuracy<0.1%FS<0.1%FS<0.1%FS<0.1%FS
Voltage Readback ValueMeasuring Range0-60V0-60V0-150V0-150V
Resolution1mV1mV10mV10mV
Accuracy<0.1%FS<0.1%FS<0.1%FS<0.1%FS
Power Readback ValueMeasuring Range-400W-400W-800W-800W-400W-400W-800W-800W
Resolution0.1W0.1W0.1W0.1W
Accuracy<1.0%FS<1.0%FS<1.0%FS<1.0%FS
Temperature Drift CoefficientVoltage Temperature Drift100ppm/℃100ppm/℃100ppm/℃100ppm/℃
Current Temperature Drift50ppm/℃50ppm/℃50ppm/℃50ppm/℃
Load and Power Regulation RateVoltage≤0.05%Umax≤0.05%Umax≤0.05%Umax≤0.05%Umax
Current≤0.05%Imax≤0.05%Imax≤0.05%Imax≤0.05%Imax
RippleVoltage≤100mVp-p≤100mVp-p≤300mVp-p≤300mVp-p
Current≤30mArms≤30mArms≤30mArms≤30mArms
Rise Time (10-90%)Voltage Rise (No Load)12ms6ms40ms20ms
Voltage Rise (Full Load)24ms12ms80ms40ms
Fall Time (90-10%)Voltage Fall (No Load)12ms6ms40ms20ms
Voltage Fall (Full Load)12ms6ms40ms20ms
Dynamic ResponseVoltageVoltage recovery to 0.75% (0-50%Load) ≤2msVoltage recovery to 0.75% (0-50%Load) ≤2ms
Output Protection RangeOvercurrent Protection-32A or 32A-32A or 32A-12.5A or 12.5A-12.5A or 12.5A
Overvoltage Protection63V63V155V155V
Overpower Protection-410W or 410W-810W or 810W-410W or 410W-810W or 810W
AC ParametersVoltage Range100VAC-240VAC100VAC-240VAC100VAC-240VAC100VAC-240VAC
Overvoltage Protection264VAC264VAC264VAC264VAC
Undervoltage Protection90VAC90VAC90VAC90VAC
Frequency Range47Hz-63Hz47Hz-63Hz47Hz-63Hz47Hz-63Hz
Power Factor (PF)>0.98 (Leading or Lagging)>0.98 (Leading or Lagging)
Maximum Current (rms)2Aac(220V)4Aac(220V)2Aac(220V)4Aac(220V)
DC Component-0.1A-+0.1A-0.1A-+0.1A-0.1A-+0.1A-0.1A-+0.1A
Measurement Range (Temperature)-20-120℃-20-120℃-20-120℃-20-120℃
Measurement Accuracy (Temperature)±1℃±1℃±1℃±1℃
Environmental ParametersTemperature Measurement Resolution0.1℃0.1℃0.1℃0.1℃
Operating Temperature0-40℃0-40℃0-40℃0-40℃
Storage Temperature-20-70℃-20-70℃-20-70℃-20-70℃
Noise65dB65dB65dB65dB
Maximum Efficiency (Max Input Voltage Full Load)84%86%84%86%
Communication InterfaceRS232/USB/RS485/CAN/LAN (Optional)RS232/USB/RS485/CAN/LAN (Optional)
Dimension W×D×H (mm)465×217×44mm465×217×44mm465×217×44mm465×217×44mm
Net Weight4.5kg4.5kg4.5kg4.5kg
VEM-60V/150V
VEM-60V/150V
VEM-60V/150V
VEM-60V/150V
VEM-60V/150V
+
  • VEM-60V/150V
  • VEM-60V/150V
  • VEM-60V/150V
  • VEM-60V/150V
  • VEM-60V/150V

VEM-60V/150V

The VEM series bidirectional DC power supply is a high-precision, small-sized bidirectional DC test power supply product that integrates source and load functions. The maximum output current is 30A, and the maximum output voltage can reach 600V. It has a wide range output capability when powered and the ability to feedback energy to the grid when loaded. It has the characteristics of low ripple and high dynamic response.

Contact

szwrddq@163.com

400-111-0655

Category:

Bidirectional DC Power Supply